Clock Gauge—FIG
818 / 818F Download Specification Sheet.pdf |
|
|
Clock Gauge With
Metric Face—FIG
818 The Morrison Clock Gauge is a unique, fully mechanical, liquid level indicator which can be used in a variety of applications. The standard model will measure up to a 12 ft. dimension. Originally intended for small aboveground petroleum storage tanks to eliminate the need to manually "stick" the tank. Operation is simple: the float moves up and down with the level of the product and is cabled to a wheel which drives the hands on the clock. |
|
|
Clock Gauge Alarm—FIG 918 / 918F Download Specification Sheet.pdf |
|
| Alarm—FIG 918TCP The 918 TCP provides an audible alarm for either a high or low level warning. The system incorporates an alarm box and a single-point level sensor. The alarm box is UL Listed. The alarm box is a weatherproof, intrinsically safe, 90 decibel alarm that operates on two 9-volt batteries. It features a membrane-type test/cancel button. The single point level sensor is designed for tanks up to 35’ tall. This rugged sensor is immersed in the tank through a 2" NPT female opening and is supported by a nylon liquid tight fitting, Teflon tubing and wire. The float and weight are stainless steel, making it ideal for almost any petroleum tank application. The high or low activation is set at the factory. The order length should be equal to the distance from the top of the 2" tank opening to the desired activation level. |
|
|
The Fig. 1018 Mechanical AST Gauge is designed for use on aboveground storage tanks. This quality gauge provides a convenient and economical solution to inventory management needs. The standard gauge unit can be calibrated for tanks up to 35 ft. in height, eliminating costly custom probe lengths used in other gauging systems.
|
![]() |
|
Simplex Tank Gauge—FIG 618 Download Specification Sheet.pdf |
|
|
Mechanical AST Gauge—Steil Safety Gauge FIG
SGE92
|
|
AST Overfill
Prevention Valve—FIG 9095A The Morrison 9095A Series is now approved with the City of New York Fire Department (Approval #5028). Download Specification Sheet.pdf |
|
|
AST Overfill
Prevention Valve Test Mechanism—FIG 9095ATM
The
new test mechanism option for the 9095A allows a technician to verify
that the valve is functioning properly without having to climb on the
tank or uninstall the valve. As a part of an ongoing tank maintenance
program, one can verify the valve is working properly by pulling on
the test line at any time during the filling process to actuate the
float and stop the fill. |
![]() |
AST Overfill
Prevention Valve—2" FIG 9095S
|
|||
| Overfill Warning
Valve for Waste Oil Systems—FIG FMM-ASO Series "FMM® brand" warning valve with optional alarm for use on waste oil evacuation systems which use an air operated pump. The FMM Series is ULC Listed. Download Specification Sheet.pdf |
|
||
|
Diffuser—FIG 539 Series Reduces turbulence of fuel in storage tanks, thus minimizing vapor creation. Reduces fuel contamination by directing flow away from debris on tank bottom. Saves on both fluid vaporization and wear and tear of tanks. Does not restrict flow of liquid into tank. Easily assembles to standard aluminum drop tube with screws or threaded pipe attachment. Variety of models available for both AST and UST applications. Download
Specification
Sheet.pdf |
![]() |
| Pressure/Vacuum
Emergency Vent—FIG 143/143A Series Emergency Vent with both pressure and vacuum relief for use on aboveground storage tanks. Emergency vacuum relief can be utilized as a backup to the "normal" vent. |
![]() |
|
Emergency
Vents and Vent Fittings—FIG 244 Series Download Specification
Sheets |
![]() |
|
Pressure/Vacuum
Vent—FIG 749 Series Download Specification Sheet.pdf |
|
|
Pressure/Vacuum
Vent With Gauge Hatch—FIG 548 Series Download Specification Sheet.pdf |
|
|
Pressure/Vacuum
Vent—FIG 748 Series Download Specification Sheet.pdf |
|
| Combination
Vent/Overfill Alarm—FIG 922 This innovative product is for use on aboveground storage tanks and combines a pressure/vacuum vent and overfill alarm all in one unit. Download Specification Sheet.pdf |
|
| Double Outlet
Vent—FIG 155 Series Aluminum T-style Vent used primarily on small fuel oil storage tanks. Outlet ports on either side of the inlet with 20 mesh stainless steel screen keeps debris out of the airway. |
|
| Updraft Vent—FIG 354 "Open" vent used on underground and aboveground tanks for motor fueling. Vent allows tank to "breathe" during filling/dispensing operations. Some sizes are CARB approved. |
|
| Flame Arrester—FIG 351S Used in conjunction with a "normal" vent on aboveground storage tanks. Open (non-pressure type) flame arrester to help prevent the transmission of heat and/or an ignition source into the tank. |
|
|
AST Spill Container—FIG 515
& 517 / 518 Series Download 515 Specification
Sheet.pdf |
|
| Double
Tapped Bushings—FIG 184 Series Used in pipe and tank fitting to reduce or adapt to a connection. Cast iron with NPT threads. The duplex bushing is used to connect 2" pipe to dual 1/2" or 3/8" lines. |
|
|
Solenoid
Valve—FIG 710 Download Specification Sheet.pdf |
|
| 1/4"
Expansion Relief Valve—FIG 77 Used on AST piping for relief of excessive pressure due to outside temperature rise. Valve allows product to return back to storage tank. Especially suited for existing pipeline and by-passing a valve that does not have expansion relief. Brass construction. |
|
| 1/2"
Expansion Relief—FIG 78DI Used on AST piping for relief of excessive pressure. Valve allows product to return back to the storage tank. Ductile Iron construction. |
|
|
Gate
Valve (without expansion relief)—FIG 234 and 235 Download Specification Sheet.pdf |
|
|
Gate
Valve (with expansion relief)—FIG 534 and 535 Download Specification Sheet.pdf |
|
|
Quick Opening Gate Valve—FIG 237, 238 and 438 |
|
|
Ball Valve (full port)—FIG 691 Download Specification Sheet.pdf |
|
|
Caps
and Adaptors—FIG 305/305C/405/405C Series Ask about the EVR Approved Caps and Adaptors! |
|
| Anti-Siphon
Valve—FIG 910ER Used on AST to help prevent a release of product if a rupture in the line occurs below liquid level in the tank. This valve is normally closed and will resist the head pressure and assist in preventing any "siphoning" of tank contents. (due to heavy spring load needed to resist head pressure, the 910 ER is restricted to use on submerged pump (pressure) systems only. |
|
| Fusible
Globe Valve—FIG 939 Brass Globe Valve used to shut off product flow in the event of fire. Fusible element in handwheel automatically closes valve when in contact with 165° F. |
|
|
External
Emergency Valve—FIG 346 Series Download Specification Sheet.pdf |
|
|
Internal
Emergency Valve—FIG 272 Series Download Specification Sheet.pdf |
|
| Swing
Check Valve—FIG 246 Series Used for single-direction flow in a horizontal pipeline and/or to isolate product in a multi-product handling system. Poppet and seats are metal and may allow some seepage over long periods of time. Expansion relief is available. |
|
|
Frost
Proof Drain Valve—FIG 128 Series |
|
|
By-Pass Valve—FIG 174 and 174AL Series Available in brass and aluminum. NOTE: Fig. 174 and Fig. 174AL are not pressure regulating devices. |
![]() |
| Threaded
Style Fill Cap—FIG 178 Series Tight-seal style cap with threaded cover. For fill port of small storage tanks. Lockable with a padlock. Body is available in iron or brass. Cover is also available in iron or brass. Buna-N gasket. |
|
| Hinged-style
Fill Cap—FIG 179 Series Loose-seal style cap with hinged cover. For fill port of small storage tanks. Lockable with a padlock. Aluminum or cast iron. Available with male or female threads. |
|
| Combination
Fill Cap and Vent—FIG 379 Series Fill cap and open style vent used on small storage tanks. All aluminum with brass screen. |
|
| Oil
and Molasses Gate Valve—FIG 215 Series Manually operated shutoff valve designed to be used with heavy oils, light grease, molasses, honey cream and other non-flammable viscous fluids. Iron body and brass gate construction with a painted black enamel finish. Lockable with padlock. |
|
| Quick-closing
Barrel Faucet—FIG 110 UL listed barrel faucet with spring loaded poppeted shut-off. Used on barrels and utility tanks for low pressure (50 PSI maximum) or gravity flow and where quick shut-off is desired. |
|
| Barrel
Faucet - Ball Valve Type—FIG 633 and 699 Series Ball valve type (quarter turn) brass barrel faucet. Used on barrels and small utility tanks for low pressure or gravity flow operation. Lockable with a padlock. Straight or faucet styles. |
|
| Farm
Tank Emergency Valve—FIG 474 / 574 Emergency shut-off in case of fire. Male thread to tank with poppet inside tank. Angled or straight body to female threaded outlet. Fusible link holds poppet open. |
|
| Double Outlet
Vent—FIG 155 Series Aluminum T-style Vent used primarily on small fuel oil storage tanks. Outlet ports on either side of the inlet with 20 mesh stainless steel screen keeps debris out of the airway. |
|
| Double
Tapped Bushings—FIG 184 Series Used in pipe and tank fitting to reduce or adapt to a connection. Cast iron with NPT threads. The duplex bushing is used to connect 2" pipe to dual 1/2" or 3/8" lines. |
|
| Farm/Utility Nozzle—FIG 200 Manual shut-off nozzle used for 3/4" and 1" utility fueling applications (gravity or low pressure). Spouts are replaceable and available in either leaded, or unleaded sizes. |
|
| 90° Bulk Fueling
Nozzle - Dash Pot Style—FIG 189S Manual shut-off nozzle for use in 2" bulk fueling (pressure applications). Supplied with hold-open notches and dash pot design for easier opening and cushioned close. Standard spout is 9" long. 36" spout is available. Vacuum breaker (optional) allows product to flow back into tank. |
|
| 75° Bulk Fueling
Nozzle - Gravity/Low Pressure—FIG 189G Manual shut-off nozzle for use in 2" bulk fueling (gravity or low pressure applications). Supplied with hold-open notches. Standard spout is 9" long. 36" spout is available. |
|
|
To Purchase Morrison Equipment, Contact the Customer Service Department at 800.553.4840 |
![]() |